The Maintenance Inc. Online Store
|
|
|
Application Specifications: ASTM D 3405/1190 AASHTO M-301-851 Federal Specification SS-S-1401C FAA Specification P-605, Type III Coverage: Sealant required to fill 1/2" x 1/2" joint 100 linear feet, 12.3 lbs. Melting and Application Equipment: the melter unit shall be of the double boiler type equipment with an agitator, and using high flash oil, 600 degrees F (315 degrees C) minimum, as a heat transfer medium. Material kettle and oil jacket must have thermometers that have been calibrated, heating must be thermostatically controlled to hold desired temperature. The melting unit shall be equipped with a pump capable of circulating the material from the bottom to the top of the kettle. The sealing compound shall be agitated continuously during the melting and pouring process. Application Temperatures: Recommended pouring temperature 370 degrees F (180 degrees C). Safe heating temperature 390 degrees F(199 degrees C).
| ||||||||||||